Data Loggers

<< Click to Display Table of Contents >>

Navigation:  EDGE > Devices >

Data Loggers

EDGE currently supports the loggers listed in the table below. Example files can be found in the EDGE installation folder under \EDGE\Example\SensorExamples. Unlisted loggers may be supported. Send example file to EarthSoft Support for more information.

 

Device Model

Description

Supported File Types

Campbell Scientific OBS-3A and 5+

EDGE-Logger-Campbell-OBS

Any model that stores data in TOA5 format is supported.

 

Turbidity and Temperature monitoring system. Monitors sediments concentrations, logs depth, wave height, wave period, temperature, and salinity.

 

Operation Manual

 

Requires EQuIS Live

.dat

EQuIS Live

25048-Ent-Icon

Live Logger Data

 

Requires EQuIS Live

.xlsx

Generic Field Results

25048-Generic-FR

Import sample and field results data into Sample Section (data mapped to the columns available under this section) and Field Results Section (CAS_RN must be present in the RVF file; prior setup is required).

.xlsx

Geokon

EDGE-Logger-Geokon

Geokon 4500

 

Requires EQuIS Live

.csv, .cdf

Horiba U-51, U-52, U-52G, U-53, U-53G

EDGE-Logger-Horiba U-50 Series

The U-50 series of multi-parameter water quality meters are equipped to measure and log data for as many as 11 parameters simultaneously with one single probe.

 

Information Booklet

 

Real Time Data Streaming

 

.csv, .cdf

Hydrolab DS5X, DS5, MS5

EDGE-Logger-HydroLab_MS5

For water quality measurements (Temperature, DO, Conductivity, and pH; plus up to two additional sensors).

 

Technical Data

 

Real Time Data Streaming

 

.csv, .cdf

Hydrolab HL4, HL7

EDGE-Logger-Hydrolab-HL4

Multi-parameter water quality probes.

 

More Info

 

Real Time Data Streaming

 

.csv, .cdf

In-Situ Troll 9500

EDGE-Logger-In-Situ Troll 9500

Multi-parameter water quality probe (pH/ORP).

 

Operation Manual

.txt

In-Situ Level 500 (100/300/700)

EDGE-Logger-In-Situ 500

In-Situ Modbus real time data streaming

 

.csv, .cdf,

 

In-Situ-SmarTroll

EDGE-Logger-In-Situ Smartroll

In-Situ Modbus real time data streaming

.csv, .cdf

 

In-Situ Aqua Troll 200

EDGE-Logger-In-Situ 200

In-Situ Modbus real time data streaming
(also supports Aqua Troll 100, 400, 600)

 

.csv, cdf

In-Situ Level Troll

EDGE-Logger-In-Situ Level Troll

Also called Level 4000.

 

In-Situ Modbus real time data streaming
(also supports Level Troll 300, 400, 500, 700)

 

.txt

 

In-Situ BaroTroll 500, Rugged Troll 200, Rugged BaroTroll, RDO Pro,
RDO Pro-X, RDO Titan, ConTroll Pro

In-Situ Modbus real time data streaming

NA

Landtec GEM2000

EDGE-Logger-LandTec Gem2000

Handheld CO2/CH4/LEL/O2/Pressure Monitor designed for analyzing landfill gas composition and flow calculations. Monitors gas migration probes and gas extraction systems.

 

Operation Manual

 

.csv, .cdf

Landtec GEM5000

EDGE-Logger-Landtec Gem5000

This was designed specifically for use on landfills to monitor landfill gas (LFG) extraction systems, flares, and migration control systems.

 

Operation Manual

.csv, .cdf

Partisol

25048-Generic-FR

Collects standard field results.

.csv, .cdf

RASS

25048-Generic-FR

(Radio Acoustic Sounding System)

Standard field results that measure atmospheric lapse rate.

.txt

RST

EDGE-Logger-RST

Pressure and temperature readings

 

Requires EQuIS Live

.csv, .cdf

Solinst Barologger

EDGE-Logger-SolinstGoldBarologger

The Barologger Gold uses algorithms based on air pressure only. It measures and logs changes in atmospheric pressure, which are then used to compensate water level readings recorded by a Levelogger.

 

Operation Manual

 

Requires EQuIS Live

.csv, .cdf

Solinst Levelogger

EDGE-Logger-Solinst-Levelogger

Model 3001 Leveloggers measure ground water and surface water level and temperature measurements using pressure and temperature detectors.

 

Operation Manual

 

Requires EQuIS Live

.csv, .cdf

Thermo Scientific Model 43i Analyzer

EDGE-Logger-Thermo Scientific Analyzer

This is a pulsed fluorescence gas analyzer for sulfur dioxide (SO2) measurement in ambient air.

 

Operation Manual

.txt

VanEssen Mini-Diver

EDGE-Logger-VanEssen-Mini-Diver

Measures and records groundwater level and temperature.

 

Note: Discontinued

 

Operation Manual

 

Requires EQuIS Live

.csv, .cdf

YSI 556

EDGE-Logger-YSI 556

Simultaneously measures numerous water quality parameters, including temperature, conductivity, salinity, dissolved oxygen, pH, and ORP.

 

Note: The 556 MPS handheld instrument has been discontinued. YSI will continue to support existing 556’s through 2020.

 

Operation Manual

.csv

 

YSI 6600V2-4 and 6600

EDGE-Logger-YSI 6600

Measures the same parameters as the YSI 556 and also turbidity, chlorophyll, and blue-green algae. The V2-2 measures two of the four parameters simultaneously. Additional calculated parameters include total dissolved solids, resistivity, and specific conductance.

 

 

.csv

 

YSI 6820

EDGE-Logger-YSI 6820

The YSI Model 6820 simultaneously measures numerous water quality parameters, including temperature, conductivity, salinity, dissolved oxygen, pH, and ORP.


YSI 6920

EDGE-Logger-YSI 6920

Ideal for long-term in situ monitoring and profiling, including turbidity, dissolved oxygen, algae, and more.

.csv

 

YSI EXO1, EXO2

EDGE-Logger-YSI EXO1

For estuarine, surface water, or ground water applications.

 

Real Time Data Streaming

.csv

 

YSI ProPlus

EDGE-Logger-YSI ProPlus

The YSI Professional Plus handheld multi-parameter meter measures a variety of combinations for dissolved oxygen, conductivity, specific conductance, salinity, resistivity, total dissolved solids (TDS), pH, ORP, pH/ORP combination, ammonium (ammonia), nitrate, chloride and temperature. Also a very powerful lab instrument for BODs, pH and ORP.

 

Operation Manual

.csv