Field Logger Import

<< Click to Display Table of Contents >>

Navigation:  EDGE > Devices > Data Loggers >

Field Logger Import

This article explains how to import loggers that use the Field Logger EDGE section.

 

Field Logger Devices

 

Device/Model

remap_code

Extension(s)

Real-Time Data Support

Horiba U

Horiba_U

.csv, .cdf

YES

Hydrolab HL4, HL7*

Hydrolab_HL

N/A

YES

Hydrolab MS5

Hydrolab_MS5

.csv, .cdf

YES

In-Situ_Modbus (protocol)*

In-Situ_Modbus

N/A

YES

In-Situ_SmarTroll

In-Situ_SmarTroll

.csv, .cdf

YES (through In-Situ_Modbus)

YSI 556

YSI_556

.csv, .cdf

YES

YSI 6600V2

YSI_6600V2

.csv, .cdf

YES

YSI 6820

YSI_6820

.csv, .cdf

YES

YSI 6920

YSI_6920

.csv, .cdf

YES

YSI EXO1

YSI_EXO1

.csv, .cdf

YES

YSI ProPlus

YSI_ProPlus

.csv, .cdf

YES

* These devices do not support file import

 

Note: The remap_code equals the corresponding logger manufacturer found in the EDGE\Sensors\[manufacturer] folders

 

Reference Values and Remapping

 

See Create Groups for Field Results for information regarding parameters that do not require remapping.

 

As data loggers capture field result data for general field parameters, it is essential to ensure that the correct analytes and desired units for datalogger parameters are present in RT_ANALYTE, or are REMAPPED to values in RT_ANALYTE, and RT_UNIT, to allow the data to be loaded.

 

Change the external unit/cas_rn to another more desirable unit/cas_rn:

 

1.In RT_REMAP, create a new row that contains the remap_code of the desired logger (see above table for remap codes)

a.Include an accurate description

b.The example below has a remap_code of "field_logger_data"

 

25245-remapping

 

2.In RT_REMAP_DETAIL, create a row for each remap

a.remap_code: the remap_code for the desired logger that's already present in RT_REMAP

b.external_field: cas_rn if analyte, unit if unit

c.external_value: the value present in the logger being imported (i.e for example pH_1)

d.internal_value: the desired database value (i.e for example pH_1 > pH)

 

25245-rt_remap_detail

 

Once RT_UNIT, RT_ANALYTE, RT_REMAP, and RT_REMAP_DETAIL are correctly configured, export an updated Reference Values File (RVF) to EDGE. Review Create a Reference Values File for more information about this process.

 

Setup EDGE to Import Generic Field Data Logger Records

 

1.The data is imported into two tabs, one for the header information and other for the logger data.

2.To make each section present as a tab within EDGE, select the Show/Hide Tabs menu option, then check the "field_logger_data" and "Field_Logger_Data_Header" check boxes.

3.To highlight errors with missing samples, set the enumeration value in the field_logger_data_error enumeration to y. For further information on setting enumeration values, read the article on the Configuration Plugin Tool.

4.Ensure the RVF contains the analyte, unit, and remapping information discussed above.

 

Importing Logger Data to EDGE

 

1.Click the Devices tab, then click the relevant device button.

2.Click Open File and navigate to the desired data logger file.

a.A successful data load message will provide information on the number of rows that were imported, and the time taken.

 

25245-fieldloggerdataheader

 

25245-fieldloggerdata

 

3.The logger data are matched to samples in the Field Samples EDGE sections. If a sample exists for the same location and date as a record in the field_logger_data section, those records will be associated by EDGE.

a.If EDGE cannot find a Field Samples record from the same location and date, that row will be marked with an error: "Warning: Unable to find a corresponding sample record for the logger data." This can be resolved by either:

i.click the Create Missing Samples button; this will create additional Field Samples records to match the logger data.

 

25245-createMissingSamples

 

ii.Remove the depth record from the logger section

 

Notes:

Clicking between different EDGE sections will refresh the field_logger_data tab and check for matching samples

Users can import multiple loggers in one session

 

4.Once any errors have been resolved, the EDD may be exported from EDGE.

 

Loading Into EDP

 

For guidance in loading data to the database, please go to Importing Logger Data to the Database.

 

Device Specific Differences:

 

YSI Importing without Remap

 

This EDGE option, when set to False will only import a column if there is remap available in the RVF.

 

1.Go to Options -> Sensor -> Import Without Remap, which by default is set to True.

2.Set to False.

3.Import.