EQuIS Geotech - CPT/DMT Data Review (BETA) Widget

<< Click to Display Table of Contents >>

Navigation:  Geotech > Widgets >

EQuIS Geotech - CPT/DMT Data Review (BETA) Widget

The EQuIS Geotech - CPT/DMT Data Review (BETA) widget allows users to review and edit selected Cone Penetration Test (CPT) and Dilatometer Test (DMT) data collected during field activities. Users can confirm apparent CPT rod breaks and change records relating to:

CPT and DMT Water Depth

CPT Dissipation Initial Pore Pressure Override, Duration, and Duration Unit

 

EQuIS Geotech Schema and licensing are required to use this widget.

 

Note: The widget is available in the Widget Chooser but can only be added to a dashboard by users assigned to the Admin role. Users without appropriate permissions will not be able to use the widget to modify data.

 

The widget is designed to save a default note based on the user action to the DT_NOTE.NOTE_TEXT field to serve as a record of the changes made to the database via the widget.

 

Note: A NOTE_TYPE = “Geo_CPT_DMT_Revision” record is needed in the RT_NOTE_TYPE reference table for the widget to be able to save changes to the database and generate the comment record.

 

These changes can be examined with the Geotechnical Widget Data Revisions report.

 

This article contains the following:

Widget Interface

CPT ROD BREAK Tab

CPT Tab

CPT DISSIPATION Tab

DMT Tab

Widget Properties

Known Issues

 

 

Widget Interface

 

Geo-Widget-CPT_DMT_Data_Review-Location

 

Users can view or modify records for one location at a time by selecting the desired location from the Location drop-down menu. Locations listed in the drop-down are based on the selected facility of the dashboard and have DT_LOCATION.LOC_TYPE = 'CPT' or 'DMT'. If a facility is not selected, the Location drop-down is disabled. If the selected facility does not have any CPT or DMT locations, the Location drop-down will be empty.

 

The EQuIS Geotech - CPT/DMT Data Review (BETA) widget will display the following tabs based on the location type selected:

CPT ROD BREAK

CPT

CPT DISSIPATION

DMT

 

Each tab will display a grid of data for review and editing. Grids on these tabs have a paging control for displaying a limited number of items at a time (10 by default).  

 

Filtering – Beneath some column headers in the grid is a filter box that filters on that column only. Enter a search term (one or more characters) in the appropriate search box beneath the column header. Only records that contain the search term will be displayed. Filtering is cumulative if multiple columns are filtered.

 

The widget can also be configured to only view the data and not allow users to edit data (see Widget Properties section below).

 

 

CPT ROD BREAK Tab

 

This tab is only available when a CPT location is selected.

 

Geo-Widget-CPT_DMT_Data_Review-Rod_Break

 

The CPT ROD BREAK tab displays a grid with data returned from the Geotechnical CPT Apparent Rod Breaks report (EQUIS.GEOTECH_CPT_ROD_BREAK database function contained in the Geotechnical Schema) where parameter

@facility_id is the currently selected facility and

@sys_loc_code is the selected location in the Location drop-down.

 

Columns displayed in the grid from the report are Depth, Depth Unit, Qc, Fs, and Apparent Rod Break. These columns are not editable. Each column width in the grid can be configured in the Widget Editor (see Widget Properties section below).

 

Records denoted by the function report as containing an apparent rod break have an 'X' value in the Apparent Rod Break column. Use the column filtering to identify these records.

 

The Confirm Rod Break column is editable and allows the users to mark the row as a confirmed rod break. This field maps to DT_DOWNHOLE_POINT_DATA.REPORTABLE_YN. When a user selects a checkbox to confirm a rod break, the Update Ent-Save_Icon icon on the grid frame is enabled. Click Update to save changes to the database.

 

Note: Records edited in the widget grid will NOT be updated in the database until the user selects the Update (i.e., Save) icon and adds a required note.

 

Upon clicking the Update Ent-Save_Icon icon, a dialog box appears with the default note of 'Rod Break Update'. This default note can be augmented to include more content but a note is required. Clicking Cancel closes the dialog box and no changes have been made to the database. Clicking OK updates the database.

 

The note is added to the DT_NOTE table for the selected facility with the following properties:

NOTE_TYPE = 'Geo_CPT_DMT_Revision'

NOTE_TEXT = 'Rod Break Update' (or note as modified by the user)

DB_RECORD_ID = Session FACILITY_ID

CONTACT_1 = USER_NAME

CREATED_DATE = Date and time the note was added to the database via the widget

 

 

CPT Tab

 

This tab is only available when a CPT location is selected.

 

geo-widget-cpt_dmt_data_review-cpt_zoom40

 

The CPT tab contains two grids:

Top Grid – The top grid displays WATER_DEPTH (Water Depth), DEPTH_UNIT (Depth Unit), and CUSTOM_FIELD_1 (Measured Water Depth) from the DT_WATER_TABLE table for the selected location and facility. All fields in this grid are editable unless the "Allow editing" option is unchecked in the widget settings. Measured Water Depth is checked if DT_WATER_TABLE.CUSTOM_FIELD_1 = 'measured' (not case sensitive). If no data are available to display, an empty row will be provided to add data.

Bottom Grid – The bottom grid is always read only and displays results from the Geotechnical CPT Data report (EQUIS.GEOTECH_CPT_DATA database function contained in the Geotechnical Schema). Updates to the top grid will be reflected in this grid after saving and the report loads again.

 

When a user edits a field in the Top Grid, the Update Ent-Save_Icon icon on the grid frame is enabled. Click Update to save changes to the database.

 

Note: Records edited in the widget grid will NOT be updated in the database until the user selects the Update
(i.e., Save) icon and adds a required note.

 

Upon clicking the Update Ent-Save_Icon icon, a dialog box appears with the default note of 'CPT Water Depth updated'. This default note can be augmented to include more content but a note is required. Clicking Cancel closes the dialog box and no changes have been made to the database. Clicking OK updates the database.

 

The note is added to the DT_NOTE table for the selected facility with the following properties:

NOTE_TYPE = 'Geo_CPT_DMT_Revision'

NOTE_TEXT = 'CPT Water Depth updated' (or note as modified by the user)

DB_RECORD_ID = Session FACILITY_ID

CONTACT_1 = USER_NAME

CREATED_DATE = Date and time the note was added to the database via the widget

 

 

CPT DISSIPATION Tab

 

This tab is only available when a CPT location is selected.

 

geo-widget-cpt_dmt_data_review-cpt_disp_zoom45

 

The CPT Dissipation tab contains two grids:

Top Grid – The top grid is always read only and displays DEPTH (Test Depth), and DEPTH_UNIT (Depth Unit) from the Geotechnical CPT Dissipation Data report (EQUIS.GEOTECH_CPT_DISSIPATION_DATA database function contained in the Geotechnical Schema). The grid also shows PARAM_VALUE where PARAM_CODE = 'cpt_dis_init_pp_over' (Initial Pore Pressure Override), PARAM_VALUE where PARAM_CODE = 'duration' (Duration), and PARAM_UNIT where PARAM_CODE = 'duration' (Duration Unit) from the DT_GEO_TEST_PARAMETER table. Initial Pore Pressure Override, Duration, and Duration Unit are editable unless the "Allow editing" option is unchecked in the widget settings.

Bottom Grid – The bottom grid is always read only and displays DEPTH (Test Depth), ELAPSED_TIME_SEC (Time), PORE_PRESSURE (Pore Pressure), NORMALIZED_EXCESS_PORE (Normalized Excess Pore Pressure), and PORE_PRESSURE_UNIT (Pore Pressure Unit) from the Geotechnical CPT Dissipation Data report. Updates to the top grid will be reflected in this grid after saving and the report loads again.

 

When a user edits a field in the Top Grid, the Update Ent-Save_Icon icon on the grid frame is enabled. Click Update to save changes to the database.

 

Note: Records edited in the widget grid will NOT be updated in the database until the user selects the Update
(i.e., Save) icon and adds a required note.

 

Upon clicking the Update Ent-Save_Icon icon, a dialog box appears with the default note of 'CPT Dissipation update'. This default note can be augmented to include more content but a note is required. Clicking Cancel closes the dialog box and no changes have been made to the database. Clicking OK updates the database.

 

The note is added to the DT_NOTE table for the selected facility with the following properties:

NOTE_TYPE = 'Geo_CPT_DMT_Revision'

NOTE_TEXT = 'CPT Dissipation update' (or note as modified by the user)

DB_RECORD_ID = Session FACILITY_ID

CONTACT_1 = USER_NAME

CREATED_DATE = Date and time the note was added to the database via the widget

 

 

DMT Tab

 

This tab is only available when a DMT location is selected.

 

geo-widget-cpt_dmt_data_review-dmt_zoom40

 

The DMT tab contains two grids:

Top Grid – The top grid displays WATER_DEPTH (Water Depth), DEPTH_UNIT (Depth Unit), and CUSTOM_FIELD_1 (Measured Water Depth) from the DT_WATER_TABLE table for the selected location and facility. All fields in this grid are editable unless the "Allow editing" option is unchecked in the widget settings. Measured Water Depth is checked if DT_WATER_TABLE.CUSTOM_FIELD_1 = 'measured' (not case sensitive). If no data are available to display, an empty row will be provided to add data.

Bottom Grid – The bottom grid is always read only and displays results from the Geotechnical DMT Data report (EQUIS.GEOTECH_DMT_DATA database function contained in the Geotechnical Schema). Updates to the top grid will be reflected in this grid after saving and the report loads again.

 

When a user edits a field in the Top Grid, the Update Ent-Save_Icon icon on the grid frame is enabled. Click Update to save changes to the database.

 

Note: Records edited in the widget grid will NOT be updated in the database until the user selects the Update
(i.e., Save) icon and adds a required note.

 

Upon clicking the Update Ent-Save_Icon icon, a dialog box appears with the default note of 'DMT Water Depth updated'. This default note can be augmented to include more content but a note is required. Clicking Cancel closes the dialog box and no changes have been made to the database. Clicking OK updates the database.

 

The note is added to the DT_NOTE table for the selected facility with the following properties:

NOTE_TYPE = 'Geo_CPT_DMT_Revision'

NOTE_TEXT = 'DMT Water Depth updated' (or note as modified by the user)

DB_RECORD_ID = Session FACILITY_ID

CONTACT_1 = USER_NAME

CREATED_DATE = Date and time the note was added to the database via the widget

 

 

Widget Properties

 

To set which columns to display in the widget, open the Widget Editor by selecting the More Options Ent-More_Options-Icon icon in the upper right corner of the widget and then select the Edit menu option.

 

Geo-Widget-CPT_DMT-Data_Entry-Widget_Editor

 

Allow editing – When unchecked, will disable editing any grid in the widget. Checked by default to enable editing of editable fields.

 

The width of each column in the CPT ROD BREAK grid can be set by the user.

 

Widget Title – By default, the widget title is EQuIS Geotech - Lithology Editor (BETA). The title can be modified.  

Widget ThemeEnt-Theme_Color_Icon(next to the Widget Title) – Change the widget color.

Object Editor Ent-Widget-Editor_Properties – Set various appearance properties of the widget via the Widget Object Editor.

Help Ent-Help-Icon – Launch online documentation for the widget.

Copy Settings Ent-Copy_Settings-Icon Copy widget settings from another widget of the same type.

Close without Saving Ent-Close_icon – Exit the Widget Editor without saving changes.

Save Ent-Widget_Save-Icon – Apply Changes and close the Widget Editor.

 

 

Known Issues

 

Users must click in the table header region to enable the Save button.

Non-editable fields should display with a grey background.

Widget Settings are specific to only the CPT Rod Break table.

Significant performance lag when the number of records to display per page is greater than 100.

In some instances, columns in the CPT tab do not automatically resize.