<< Click to Display Table of Contents >> Navigation: Release Notes > Unsupported Builds > Build 19144 (May 2019) > EDGE (7.0.0.19144) |
FieldSampleForm: Auto-populates SAMPLE_DATE Although Autofill Dates Option = FALSE [m154086]
Fixed an issue on the FieldSampleForm where the SAMPLE_DATE field was being auto-populated with the current data and time although the "Autofill Date/Time Fields" option had been set to False.
Add dt_person and dt_equipment to EDGE Configuration Format [m157478]
dt_person and dt_equipment added to EDGE Configuration Format.
EDGE: Create Nesting EDGE\EDP Exports Folders in My EQuIS Work [m160284]
Fixed issue where EDGE working folders were creating a nesting structure.
COC Manager: Clicking Shipping Company Makes Laboratory Information Disappear [m160656]
Fixed the issue with Laboratory information vanishing after clicking Shipping Company in COC Manager.
EDGE Map: Remove Unsupported Coordinate Types [m161202]
Since only Lat/Long coordinate types are supported in the EDGE Map, added a filter to COORD_TYPE in the Location Navigator to only use Lat/Long coordinate types.
EDGE Format: Add ABANDONMENT_DATE to Well_v1 [m163183]
A new field, ABANDONMENT_DATE, has been added to the Well section of the EDGE format and Geology format.
Field Sample Form: Refresh Issue with COC Manager [m164947]
COC information (COCs, MAGs, and Containers) in Field Sample Form and Tab FieldSamples will be refreshed if user make any change in COC Manager.
Solinst Barologger and Levelogger Devices: Barometric Compensation and SYS_LOC_CODE [m165465]
Levelogger devices that use corresponding barometric pressure values from a linked Barologger no longer require matching SYS_LOC_CODE values.
EDGE Image Viewer: Photo Library Update [m165496]
Updated the Image Viewer functionality to include filtering by location selection.
EDGE Format: Add New Fields AIR_VOLUME and AIR_VOLUME_UNIT [m166478]
New fields (AIR_VOLUME and AIR_VOLUME_UNIT) have been added to the FieldSample section of the EDGE format.
EDGE Format: Cannot Change a SYS_SAMPLE_CODE Containing Apostrophes [m167656]
Fixed a bug in EDGE format that was not permitting users to change a SYS_SAMPLE_CODE if it contains apostrophes.
Issue with Importing Data from Probe Using Shortcut Key (F5) in FieldSampleForm [m168083]
Fixed the issue of importing data from probes by using shortcut key (F5)
EDGE: Read Sampler from FieldSampleForm Instead of GeneralInfo Tab for COCID Generation [m168190]
Added ability to read sampler from General_Info Table or Field Sample Form.
Field Sample Form: Importing Data from Sensor Causes Duplicate Row [m168216]
Fixed an issue that was creating a duplicate row in the Field Sample Form when importing data from sensors.
EDGE: Accurate Purge Volume Calculations [m168223]
Updated conversion factor values in water level purge calculations to use exact decimal places.
Cannot Open Attached Compressed File when Opened as EDD [m168249]
Fixed an issue where attachments would not open in EDGE when using a zipped EDD.
EDGE Configuration: Duplicate Entries in Drop-down Menus in Format Sections [m168261]
Fixed an issue where duplicate parameters were added to the drop-down menu in the Foreign Filter column in the Format Sections of the EDGE Configuration window.
Fix Issue with Special Characters in COC ID [m168664]
When special characters are used in a COC ID, the special characters are preserved in the COC ID but are replaced in the COC file name by "_" to facilitate data loading.
COC Manager Window: COC ID Cannot Be Updated [m168878]
Fixed an issue with populating the Lab and Samplers using the Update ID option in the COC Manager window.
EDGE: Generic Live Logger Interface Not Working [m168908]
Added support to import Generic Live Logger data from CSV file.
COC Manager: Detach Exported COC Does Not Work [m169000]
Fixed a bug when using the COC Detach button in the COC Manager
COC Manager: Update COC ID Removes COC Information [m169156]
Deactivated the COC ID box in COC Information table in the COC Manager to prevent removal of COC information.
WaterLevel_Purge Calculation Issues [m170705]
Updated FLOWCELL_PURGE_TIME_MIN calculation to round to 2 decimal places, Fixed issue with comparing of like units for volume and purge rates.
EDGE Configuration Format: Add DT_PERSON and DT_EQUIPMENT [m171683]
DT_PERSON and DT_EQUIPMENT added to the EDGE Configuration Format.
EDGE Enumerations: Added EDGE_FacLocDateType [m171781]
Added new SampleID_Schema "EDGE_FacLocDateType".
EDGE Stabilization Criteria Formula Includes RPD [m171915]
Added relative percent difference (RPD) formula as a stabilization criterion, which works with at least two readings. Users can define two formulas for stabilization and can determine which to use for stabilization when specific data entered as a reading.