Live Circular Gauge Widget

<< Click to Display Table of Contents >>

Navigation:  Live > Widgets >

Live Circular Gauge Widget

The EQuIS Live - Circular Gauge widget shows the latest real-time data retrieved from a selected series, as well as the minimum and maximum values it has captured. The widget will automatically update at set intervals (either user-specified, or based on DT_LOGGER.TRANSMIT_PERIOD_S).

 

Live-Circular_Gauge

 

Widget Editor

 

To open the Widget Editor, select the More Options Live-More_Options-Icon icon in the upper right corner of the widget to open the drop-down menu and then select the Edit menu option.

 

Gauge Tab

Live-Circ_Gauge_Widget-Editor

To add a logger series, make selections in the Gauge tab:

Facilities – Select the facility for which the loggers should be chosen.

Loggers – Select the logger to be tracked in the gauge.

Series – Select the data series from the selected logger to display in the gauge.

Refresh Time/Time Interval – Set the number and interval for the gauge to refresh (e.g., to get a 15-minute interval, set a Refresh Time of “15” and a Time Interval of “Minutes”, or set a Refresh Time of “900” and a Time Interval of “Seconds”).

Start Date – User can select date and pull data from the same. If the start date is not specified, then all data is pulled.

 

Options Tab

Live-Circ_Gauge_Widget-Editor2

The Options tab has the following parameters:

Initial Scale Min (optional) – Set the minimum value for the gauge scale. If a value is recorded below the minimum value, the gauge scale will update automatically with that value.

Initial Scale Max (optional) – Set the maximum value for the gauge scale. If a value is recorded above the maximum value, the gauge scale will update automatically with that value.

Range Min – Set this value to show when the series goes below an expected threshold; defaults to DT_LOGGER_SERIES TYPICAL_MIN_VALUE.

Range Max – Set this value to show when the series goes beyond an expected threshold; defaults to DT_LOGGER_SERIES TYPICAL_MAX_VALUE.

Major Interval – Set the major intervals on the gauge; defaults to 10.

Size – Two sizes are available for the circular gauge: Large and small.

 

Colors Tab

Live-Circ_Gauge_Widget-Editor3

The Colors tab allows the user to select the colors for several of the gauge's following features:

Primary – Select the colors for the Main Needle border and current value label.

Secondary – Select various border colors.

Scale – Select the color for the tick marks.

Labels – Select the color for major tick values and other labels.

Main Needle – Select the color for the Main Needle and cap.

Min/Max Markers – Select the color for Minimum and Maximum markers.

Gauge Background – Select the color for the gauge background.