Stiff Diagram Form

<< Click to Display Table of Contents >>

Navigation:  EQuIS Library > Forms > EarthSoft Standard Forms by Module > Standard with EnviroInsite Module >

Stiff Diagram Form

Form Name: Stiff Diagram

File Name: EarthSoft.Forms.Library.EnviroInsite.dll

Software: EQuIS Professional, EnviroInsite

Source: EnviroInsite install

 

Description: The Stiff Diagram Form produces a conventional Stiff diagram for a set of user-selected anions and cations.

 

Installation Instructions: The Stiff Diagram form is part of the EarthSoft.Forms.Library.EnviroInsite.dll assembly. This assembly is deployed into the EQuIS Professional installation directory when EnviroInsite is installed (C:\Program Files\EarthSoft\EQuIS\ or (for per-user installation) %localappdata%\Programs\EarthSoft\EQuIS\). For non default installations, this assembly should be copied into the custom EQuIS Professional installation directory.

 

Instructions:

This form report requires that sample interval depths and elevations be associated with all measured data per instructions in this article.

 

Input Parameters: The following parameters may be selected from the standard EQuIS parameter selection interface. After the Stiff diagram has been plotted, users may elect to double-click on the resulting diagram to display the Stiff Diagram property dialog box. The property dialog box contains additional properties that are not accessible from the EQuIS Interface. Documentation of the properties in the Stiff Diagram property dialog box are contained in the EnviroInsite documentation.

 

Parameters

Description

Required?

Format


 

  Axis Max Value

Enter the diagram axis max concentration (typically in meg/L).

YES

  Axis Tick Interval

Enter the diagram axis tick interval.

YES

  Text Height

Enter the diagram text height.

YES

  Number of Stiff Diagrams
  per Page

Enter the number of Stiff diagrams per page. Stiff diagrams in excess are generated on subsequent pages.

YES

Anions


 

  1

Select one or two anions for first row of each Stiff diagram, where anions identified based on negative equivalent weight values.

YES

  2

Select one or two anions for second row of each Stiff diagram.

YES

  3

Select one or two anions for third row of each Stiff diagram.

YES

  4

Select one or two anions for fourth row of each Stiff diagram.

NO

Cations


 

  1

Select one or two cations for first row of each Stiff diagram, where cations identified based on positive equivalent weight values.

YES

  2

Select one or two cations for second row of each Stiff diagram.

YES

  3

Select one or two cations for third row of each Stiff diagram.

YES

  4

Select one or two cations for fourth row of each Stiff diagram.

NO

Data


 

  Fraction

Select the fraction value used to filter based on DT_TEST.FRACTION.

YES

  Matrix

Select the matrix value used to filter based on DT_SAMPLE.MATRIX.

YES

Location


 

  Individual(s)

Enter individual locations to be plotted in the Stiff diagram.

NO

  Group(s)

Enter one or more location groups.

NO

Sample


 

  Type

Enter sample type.

NO

  Date Range


 

     Start Date

Enter start date.

YES

    End Date

Enter end date, where selection includes samples taken on either sample or end date.

YES

  Task

Select one or more sample tasks.

NO

  Task Code 2(s)

Select one or more task code 2 values.

NO

  Field SDG(s)

Select one or more field SDGs.

NO

Test


 

  Method(s)

Enter one or more test methods.

NO

  Column Number(s)

Enter one or more test column numbers.

NO

  Type(s)

Select one or more test types.

NO

  Lab Matrix(ces)

Select one or more test lab matrices.

NO

  Prep Method(s)

Select one or more preparation methods.

NO

  Lab SDG(s)

Select one or more lab SDGs.

NO

Result


 

  Type(s)

Select one or more result types.

NO

  Non-Detect Multipliers

Enter the non-detect multiplier to be used in designation of values for flagged non-detect results.

YES

  Reportable

Select reportable values.

NO

  Validated

Select one or more validated values.

NO

 

Data Requirements: Concentrations of cations and anions are converted from mass-based to equivalent-based values using entered values of equivalent weight in populated RT_ANALYTE_DETAIL.EQUIVALENT_WEIGHT fields. Only analytes for which RT_ANALYTE_DETAIL.EQUIVALENT_WEIGHT has been populated will be available for selection within the report. EnviroInsite expects that the equivalent weight of anions will be entered as negative quantities, while cations will carry positive equivalent weight values.

 

Example Output: View the following example or contact EarthSoft Support.

 

30329-stiff_diagr_ex_outpt